Location:Home > Produce center > Electric power security > 发电机、制氢站氢气监测

XMTC Online gas purity analyzer

XMTC Online gas purity analyzer

Product introduction

XMTC Digitization online purity analyzer is exclusively used in the fields of electric power, petrochemical, natural gas, metallurgy and others. This analyzer is divided into types of single-range and three-range, providing users a more convenient and flexible choice. Compared with other purity instruments of the same type, it is equipped with function of analog signal output as well as digital signal output. For the sake of meeting all users with different needs, various ranges of measurement from ppm grade to 100% content are designed. This set of equipment can also be additionally allocated with optional precision or explosion-proof pressure transmitters for special needs of users which can directly detect the pressure of hydrogen pipeline. The value panel has been installed on the transmitter while the measured data can be transferred locally or remotely.

Performance characteristics

XMTC is an online purity analyzer with the minimum calibration workload in the world.

XMTC is equipped with functions of digital output and analog signal output simultaneously, and data can be directly sent to DCS as well as data communication with remote computer

With characteristic of super oil-pollution resistance—the transmitter will not be affected even if its chamber is soaked by oil.

Adoption of stainless steel connecting pipe fittings with good airtightness, high security and reliability

Gas pressure, gas purity and device explosion can be measured by XMTCA at the same time.


Technical parameters

Measuring range of three-range online XMTC digitization purity instrument:

Measuring range of H2 content in CO2: 0%-100% with accuracy ±0.5%

Measuring range of air content in CO2: 0%-100% with accuracy ±0.5%

Measuring range of H2 purity in hydrogen cooling generator in operation: 90%-100% with accuracy ±0.1%

Sample velocity range: 50-200 mL/min (recommended velocity: 150mL/min)

The influence of sample gas velocity: within the range of 50-200mL/min, the effect to the measurement result will be less than 0.5% of the scale span.

Cable: the standard configuration is three-core cable of 3 meters. Maximum length is up to 1200 meters.

Analog output: 4-20mA

Data communication: RS232

Display mode: LCD screen

Ambient temperature: the standard range is -10℃--+50℃ with an optional range of -10℃--+65℃

Explosion-proof mark: Exd IIC T6 Gb

Explosion-proof type: Exd IIC T6

Interface caliber of signal wire: Φ8

Power supply: AC220V±10%, 300W

Casing protection grade: IP54

Total weight: about 100kg

Outline dimensions: length * width * height = 800×500×1600 (mm)